Specifications – Honeywell T4398B User Manual

Page 2

Advertising
background image

T4398A,B PRECISION ELECTRIC HEATING THERMOSTAT

69-1604

2

SPECIFICATIONS

Models:

T4398A: Makes heating circuit on temperature fall. With

setting knob at far left (counterclockwise) position, pro-

vides calibration-free frost protection setting of 40°F
(4°C). See Fig. 2.

T4398B: Makes heating circuit on temperature fall. With

setting knob at Off position, provides double line break
for fuse-protected 240V heating circuits. (See Fig. 3.)

Both models feature optional thermometer, located in the

cover, to indicate the actual room temperature.

Accessories (Not Included):

272804A Range Stop and Cover Locking Assembly:

Allows field-selection of minimum and maximum tem-

perature settings. Includes range stop assembly, cover

locking-screws and wrench.

Setting Range:

Fahrenheit Models: Indicates range of 50°F to 80°F with

marking indications in 5°F increments.

Celsius Models: Indicates range of 10°C to 25°C with

marking indications in 1°C increments.

Differential:

Approximately 2°F (1°C) mechanical and thermal, non-adjust-

able.

Switch Type:
Enclosed industrial-grade Micro Switch˜™ snap switch.

T4398A: Single-line break (single-pole, single-throw).

T4398B: Double-pole, single-throw with double-line break

(double-pole, single-throw) in Off position.

Wiring Connections:
Six-inch (150 mm) stranded copper leadwires suitable for con-

necting to aluminum wiring if approved special service CO/

ALR connectors are used.

Electrical Rating:

22A non-inductive at 120/208/240 Vac.
19A non-inductive at 277 Vac.

Canadian Standards Association Performance Rating:

20A at 120/208/240 Vac.

Approval Ratings:

Underwriters Laboratories Inc: Listed; file no. E47434,

guide no. XAPX.

Canadian Standards Association: File no. LR1322.

Mounting:

Direct mounting on NEMA standard vertical 2 in. x 4 in. switch

box, or 4 in. x 4 in. box using 6-32 slot Robertson™

screws.

Sensing Element:

Vapor-filled, hermetically-sealed, stainless steel, dual dia-

phragm.

Thermometer (Optional):

Coil bimetal 50°F to 90°F (10°C to 30°C).

Barometric Sensitivity:

1°F/500 ft (0.3°C/kPa).

Dimensions:

See Fig. 1.

Fig. 1. T4398A,B dimensions in in. (mm).

M5795A

FRONT VIEW

SIDE VIEW

80

70

60

50

˚F

4-3/8
(111)

2-7/8 (73)

1-1/2

(39)

1-3/4

(48)

3/4

(19)

1/2 (13)

1/2 (13)

2-1/8

(54)

3-1/4

(83)

Advertising