69-1012

The furnace cycles too frequently or
the system cycle length is too short
or too long.

■

Readjust system on-time according to instructions on
pages 18 and 19.

The thermostat's current setting
does not match the display
temperature to within

±

1

°

.

■

Check that the wiring hole in the wall behind the wallplate
was plugged with insulation to prevent drafts that might
adversely affect the thermostat operation.

■

Be aware that it is normal for the current setting and
display temperature to differ on occasion.

■

During recovery from setback or setup, setting and
display temperatures may differ for up to 30 minutes after
recovery period.

Incorrect room temperature showing
on thermostat display.

■

Make sure the hole behind the thermostat is plugged with
insulation to help prevent drafts from adversely affecting
the thermostat operation.

■

The thermostat is factory-calibrated, and cannot be
adjusted.

bAt Lo remains on display after
fresh batteries are installed.

■

Remove the batteries. Wait one hour. Install fresh alkaline
batteries.