8. electrical service guide for 230 vac model, 9. installing wire spool and adjusting hub tension – Hobart Welding Products OM-944 196 639G User Manual

Page 21

Advertising
background image

OM-944 Page 17

Return To Table Of Contents

4-8. Electrical Service Guide For 230 VAC Model

Input Voltage

230

Input Amperes At Rated Output

20

Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes

20

Min Input Conductor Size In AWG/Kcmil

14

Max Recommended Input Conductor Length In Feet (Meters)

66 (20)

Min Grounding Conductor Size In AWG/Kcmil

12

Reference: 1996 National Electrical Code (NEC)

S-0092-J

4-9. Installing Wire Spool And Adjusting Hub Tension

When a slight force is needed

to turn spool, tension is set.

1/2 in

Tools Needed:

803 012 / 803 013 -B / Ref. 802 971-C

Installing 8 in (203 mm) Wire Spool

Installing 4 in (102 mm) Wire Spool

When a slight force is needed

to turn spool, tension is set.

Retaining ring used

with 8 in (203 mm)

spool only.

Adapter used with

8 in (203 mm)

spool only.