8-2.

Typical MIG Process Control Settings

These settings are guidelines only. Material and wire type, joint design, fitup,

position, shielding gas, etc. affect settings. Test welds to be sure they comply to

specifications.

NOTE

3.5 x 125 A = 437 ipm

2 x 125 A = 250 ipm

1.6 x 125 A = 200 ipm

30 − 90 A

40 − 145 A
50 − 180 A

Convert Material

Thickness to

Amperage (A)

Material thickness determines weld

parameters.

.035 in

Recommendation

Wire Speed

(Approx.)

1/8 or 0.125 in

(0.001 in = 1 ampere)

0.125 in = 125 A

Wire Size

Amperage Range

0.023 in
0.030 in
0.035 in

Select Wire Size

Wire

Size

0.023 in
0.030 in
0.035 in

3.5 in per ampere

2 in per ampere

1.6 in per ampere

Select Wire Speed

(Amperage)

125 A based on 1/8 in

material thickness

ipm = inches per minute

Low voltage: wire stubs into work

High voltage: arc is unstable (spatter)

Set voltage midway between high/low voltage

Select Voltage

Ref. 802 439-A

Voltage controls height and width of

weld bead.

Wire speed (amperage) controls weld pe-

netration (wire speed = burn-off rate)