OM-277 Page 14

3-4.

Selecting A Location

1

Lifting Eye

2

Lifting Forks

Use lifting eye or lifting forks to
move unit.

If using lifting forks, extend forks
beyond opposite side of unit.

3

Rating Label (Non CE Models
Only)

Use rating label to determine input
power needs. Label located under
front access door.

4

Plate Label (CE Models Only)

Label located under front access
door.

5

Rating Label (CE Models
Only)

Use rating label to determine input
power needs. Label located on rear
access door (see Section 2-5).

6

Line Disconnect Device

Locate unit near correct input pow-
er supply.

Y

Special installation may be
required where gasoline or
volatile liquids are present –
see NEC Article 511 or CEC
Section 20.

3

6

18 in

(460 mm)

18 in

(460 mm)

OR

1

2

Movement

Location

4

5

3-5.

Dimensions And Weights

Dimensions

C

Height

27-1/4 in (692 mm)

D

E

Width

22-1/4 in (565 mm)

4 Holes

Depth*

35-3/4 in (908 mm)

A**

35 in (889 mm)

B***

1-1/4 in (32 mm)

C

21 in (533 mm)

A

D

1-3/16 in (30 mm)

A

E

7/16 in (11 mm) Dia

*300 Amp Model = 28-1/4 in (718 mm)
**300 Amp Model = 27-1/2 in (699 mm)
***300 Amp Model = 3/4 in (19 mm)

Weight

300 Amp

361 lbs (164 kg)

B

Ref. ST-153 556-A

450 Amp

424 lbs (192 kg)

Advertising