8. weld output terminals and selecting cable sizes – Hobart Welding Products CYBER FLEX 302 User Manual

Page 20

Advertising
background image

OM-277 Page 16

3-8.

Weld Output Terminals And Selecting Cable Sizes

Total Cable (Copper) Length In Weld Circuit Not Exceeding

100 ft (30 m) Or Less

150 ft

(45 m)

200 ft

(60 m)

250 ft

(70 m)

300 ft

(90 m)

350 ft

(105 m)

400 ft

(120 m)

Turn Off power before

connecting to weld output

terminals.

Welding

Amperes

10 – 60%

Duty

Cycle

60 – 100%

Duty Cycle

10 – 100% Duty Cycle

100

4

4

4

3

2

1

1/0

1/0

150

3

3

2

1

1/0

2/0

3/0

3/0

200

3

2

1

1/0

2/0

3/0

4/0

4/0

250

2

1

1/0

2/0

3/0

4/0

2-2/0

2-2/0

300

1

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-3/0

Negative

350

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-3/0

2-4/0

Negative

Positive CC
Terminal

400

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-4/0

2-4/0

Positive CV

500

2/0

3/0

4/0

2-2/0

2-3/0

2-4/0

3-3/0

3-3/0

Terminal

600

3/0

4/0

2-2/0

2-3/0

2-4/0

3-3/0

3-4/0

3-4/0

700

4/0

2-2/0

2-3/0

2-4/0

3-3/0

3-4/0

3-4/0

4-4/0

*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere. Contact your distributor for
the mm

2

equivalent weld cable sizes.

S-0007-E

3-9.

Remote 14 Receptacle And Terminal Strip 1T Information

Socket

Terminal

Information

A

A

24 volts ac. Protected by circuit breaker CB2.

24 VOLTS AC

B

B

Contact closure to A completes 24 volts ac contactor control circuit.

C

C

Command reference; 0 to +10 volts dc (CC), +10 volts dc (CV).

REMOTE OUTPUT CONTROL

D

D

Remote control circuit common.

E

E

0 to +10 volts dc input command signal from remote control.

F

*

Current feedback; 0 to +10 volts dc, 1 volt per 100 amperes.

H

*

Voltage feedback; 0 to +10 volts dc, 1 volt per 10 arc volts.

I

I

115 volts, 15 amperes, 60 Hz ac. Protected by circuit breaker CB1.

115 VOLTS AC

J

J

Contact closure to I completes 115 volts ac contactor control circuit.

GND

K

G

K

*

Chassis common.

Circuit common for 24 and 115 volts ac circuits.

*

L

REMOTE POWER ON/OFF

*

M

To remote On/Off switch.

*

N

Voltage sensing signal from Negative (-) weld output terminal.

REMOTE VOLTAGE SENSING

*

P

Voltage sensing signal from Positive (+) weld output terminal.

* Not Used

Advertising