Determine Sheet-Metal Requirements

The media air cleaner is adaptable to all new or existing for

forced air heating and cooling systems used in residential

applications. Some applications may require transitions,

turning vanes, or duct offsets for proper installation of the

media air cleaner.

1. Transitions

• Transitions are needed when the duct is a different

size than the air cleaner cabinet.

• Use gradual transitions to reduce air turbulence and

increase efficiency. See Fig. 12.

• Use no more than 20 degrees (about 4 in. per

running foot) of expansion on each side of the

transition fitting.

Fig. 12. Typical duct transitions.

M13643

RMAC SIZE

IN.

16 X 25

16 X 20

MM

406 X 635

406 X 508

DIM. A

14 7/16

14 7/16

367

367

DIM. B

16 3/16

16 3/16

411

411

23 1/4

18 1/4

DIM. C

591

457

DIM. D

25 1/2

20 1/2

648

521

DIM. C (SEE TABLE)

DIM. D (SEE TABLE)

DIM. B

(SEE TABLE)

DIM. A

(SEE TABLE)

1

1
8

(29)

7
8

(22)

5
8

(16)

6

3
4

(171)

7
8

(22)

IN.

MM

IN.

MM

IN.

MM

IN.

MM

20 DEGREE EXPANSION PER SIDE PER
FITTING (4 IN. PER RUNNING FOOT
[100 MM PER 300 LINEAR MM])

RETURN AIR
DUCT

TRANSITION FITTING

MEDIA AIR CLEANER CABINET

M947B

DUCT SIZE CHANGED GRADUALLY TO PREVENT TURBULENCE.