Prepare furnace for installation – Honeywell 69-1866-01 User Manual

Page 8

Advertising
background image

MEDIA AIR CLEANER

69-1866—01

8

2. Turning Vanes

• If the media air cleaner is installed next to an elbow

or angel fitting, add turning vanes inside the angle to

distribute airflow more evenly across the face of the

media. See Fig. 13.

• Turning vanes must be properly secured to prevent

movement.

3. Duct Offsets

• If the duct connection to the furnace in a side

installation is less than 7 in. you will need to add an

offset. See Fig. 14.

• Turning vanes may be required to distribute air flow

evenly.

Fig. 13. Turning vanes help distribute airflow evenly over

media.

Fig. 14. Typical use of duct offsets to make room for

media air cleaner.

Prepare Furnace for Installation

1. Disconnect power to your heating and cooling system

and remove power from any ultraviolet air treatment

system that is installed.

2. Remove and discard existing furnace filter. See Fig. 15.
3. Remove furnace blower compartment access cover.

See furnace owners' or installation manual for details.

4. Thoroughly clean the blower compartment using a

power vacuum (Shop-Vac).

NOTE: Media Air Cleaner cannot remove dirt that has set-

tled in the blower compartment and distribution

ducts.

Fig. 15. Typical use of duct offsets to make room for

media air cleaner

TURNING
VANES

M5651

M948A

LESS
THAN
7 in.
(178 mm)

OFFSET

AT LEAST
7 in.
(178 mm)

1

1 REQUIRED TURNING VANES HELP DISTRIBUTE AIRFLOW EVENLY.

M13645

FAN
ACCESS
PANEL

EXISTING 1 IN.
FURNACE
FILTER