HP TM 11-6625-2779-14&P User Manual

Page 51

Advertising
background image

PERFORMANCE CHECK TEST CARD

Hewlett-Packard Model 3555B

Tests Performed By

Transmission and Noise Measuring Set
Serial No.

Date

DESCRIPTION

CHECK

CARRIER 75 UNBAL

LEVEL ACCURACY CHECK

30Hz to 1MHz

+10dBm Range

+10dBm

±

0.5dBm

0dBm Range

0dBm

±

0.5dBm

-10dBm Range

-10dBm

±

0.5dBm

-20dBm Range

-20dBm

±

0.5dBm

-30dBm Range

-30dBm

±

0.5dBm

-40dBm Range

-40dBm

±

0.5dBm

-50dBm Range

-50dBm

±

0.5dBm

100Hz to 600kHz

+10dBm Range

+10dBm

±

0.2dBm

0dBm Range

0dBm

±

0.2dBm

-10dBm Range

-10dBm

±

0.2dBm

-20dBm Range

-20dBm ±0.2dBm

-30dBm Range

-30dBm ±0.2dBm

-40dBm Range

-40dBm ±0.2dBm

-50dBm Range

-50dBm ±0.2dBm

1MHz to 3MHz

+10dBm Range

+10dBm

±

0.5dBm

±

10% of meter indication

0dBm Range

0dBm

±

0.5dBm

±

10% of meter indication

-10dBm Range

-10dBm

±

0.5dBm

±

10% of meter indication

-20dBm Range

-20dBm

±

0.5dBm

±

10% of meter indication

-30dBm Range

-30dBm

±

0.5dBm

±

10% of meter indication

40dBm Range

-40dBm

±

0.5dBm

±

10% of meter indication

-50dBm Range

-50dBm

±

0.5dBm

±

10% of meter indication

CARRIER 135 BAL

LEVEL ACCURACY CHECK

1kHz to 600kHz

+10dBm Range

+10dBm

±

0.5dBm

0dBm Range

0dBm

±

0.5dBm

-10dBm Range

-10dBm

±

0.5dBm

-20dBm Range

-20dBm

±

0.5dBm

-30dBm Range

-30dBm

±

0.5dBm

-40dBm Range

-40dBm

±

0.5dBm

-50dBm Range

-50dBm

±

0.5dBm

10kHz to 300kHz

+10dBm Range

+10dBm

±

0.2dBm

0dBm Range

0dBm

±

0.2dBm

-10dBm Range

-10dBm

±

0.2dBm

-20dBm Range

-20dBm

±

0.2dBm

-30dBm Range

-30dBm

±

0.2dBm

-40dBm Range

-40dBm

±

0.2dBm

-50dBm Range

-50dBm

±

0.2dBm

(1)

Advertising