3-14. Selecting A Location And Connecting Input Power

Ref. 242 691-A / 802 286-E

!

Do not move or operate unit

where it could tip.

18 in (457 mm) of

space for airflow

!

Installation must meet all National

and Local Codes − have only quali-

fied persons make this installation.

!

Special installation may be

required where gasoline or volatile

liquids are present − see NEC Ar-

ticle 511 or CEC Section 20.

!

Disconnect and lockout/tagout in-

put power before connecting input

conductors from unit.

!

Always connect green or green/yel-

low conductor to supply grounding

terminal first, and never to a line

terminal.

1

Rating Label

Supply correct input power.
2

Plug (NEMA Type 6-50P)

3

Receptacle NEMA Type 6-50R)

Connect plug to receptacle.
4

Input Power Cord.

5

Black And White Input Conductor (L1

And L2)

6

Green Or Green/Yellow Grounding

Conductor

7

Disconnect Device (switch shown in

the OFF position)

8

Disconnect Device Grounding

Terminal

9

Disconnect Device Line Terminals

Connect green or green/yellow grounding

conductor to disconnect device grounding

terminal first.

Connect input conductors L1 and L2 to dis-

connect device line terminals.
10 Over-Current Protection
Select type and size of over-current

protection using Section 3-13 (fused dis-

connect switch shown).

Close and secure door on disconnect

device. Remove lockout/tagout device,

and place switch in the On position.

L1

L2

230 VAC, 1

3

1

2

4

5

6

7

8

9

10

L1

L2

1

=GND/PE Earth Ground