SECTION 5 − MAINTENANCE AND TROUBLESHOOTING
5-1. Routine Maintenance
!
Disconnect power
before maintaining.
.
Maintain more often
during severe conditions.
n = Check
Z = Change
~ = Clean
l = Replace
* To be done by Factory Authorized Service Agent
Reference
Every
3
Months
l Damaged Or Unreadable
Labels
l Cracked Parts
n l Cables
n ~ Tighten Weld
Terminal
Every
6
Months
OR
~ Inside Unit
n Remove drive roll
and apply light coat
of oil or grease to
drive motor shaft
5-2. Supplementary Protectors
Ref. 242 160-A
!
Turn Off unit.
1
Supplementary Protector CB1
CB1 protects main circuit board PC1.
2
Supplementary Protector CB2
CB2 protects the drive motor circuit
from overload. If drive motor shorts or
fails: check gun liner blockage or
kinks, check for jammed wire or bind-
ing drive rolls.
Correct problem. Press button to reset
supplementary protector.
2
1
SPOOL GUN
MIG GUN
CB2
CB1