Section 5 − maintenance and troubleshooting, 1. routine maintenance, 2. supplementary protectors – Hobart Welding Products IRONMAN 230 User Manual

Page 29

Advertising
background image

OM-235 281 Page 25

SECTION 5 − MAINTENANCE AND TROUBLESHOOTING

5-1. Routine Maintenance

!

Disconnect power

before maintaining.

.

Maintain more often
during severe conditions.

n = Check

Z = Change

~ = Clean

l = Replace

* To be done by Factory Authorized Service Agent

Reference

Every

3

Months

l Damaged Or Unreadable

Labels

l Cracked Parts

n l Cables

n ~ Tighten Weld

Terminal

Every

6

Months

OR

~ Inside Unit

n Remove drive roll

and apply light coat

of oil or grease to

drive motor shaft

5-2. Supplementary Protectors

Ref. 242 160-A

!

Turn Off unit.

1

Supplementary Protector CB1

CB1 protects main circuit board PC1.
2

Supplementary Protector CB2

CB2 protects the drive motor circuit

from overload. If drive motor shorts or

fails: check gun liner blockage or

kinks, check for jammed wire or bind-

ing drive rolls.
Correct problem. Press button to reset

supplementary protector.

2

1

SPOOL GUN

MIG GUN

CB2

CB1

Advertising