Maintenance – Husqvarna 16 User Manual

Page 34

Advertising
background image

32

– English

MAINTENANCE

IMPORTANT INFORMATION

The blades on a BioClip unit should be
set at 90 degrees to each other. In all
other cases the blades can collide and
cause serious damage to the cutting unit.

5. Version 2:

Assembly: First fit the lower belt and then the
upper belt.

Ensure the blades are positioned as set out in
the diagram, at 90 degrees to each other,
otherwise the belts must be adjusted. When the
blade bearings are loose the belts can be moved
around to the next tooth.

Tighten the nuts enough so that the bearings
rest against the cutting hood but still can be
moved.

Tension the belt by turning the eccentric adjuster
on top of the cutting hood. Tighten the nut.

Tighten all nuts on the blade bearings.

6. Version 2:

When the belt can be moved 7 mm (1/4")
inwards using a force of 10 N (2 lb) the belt is
adjusted correctly.

7. Version 1 och 2:

Fit the protective cover over the belts and
replace the parallelism arm.

Belt replacement on BioClip 90

The BioClip 90 is driven by a toothed belt that
synchronises rotation of the blades. The belt is
located under the cover of the cutting unit.

When changing the belt on a BioClip 90 follow
steps 1-7 of the above procedure for version 2.
NOTE! BioClip 90 has just 1 belt.

Belt change on cutting unit with side or rear
ejection and Combi 112

On these cutting units with "collision-proof" blades,
the blades are driven by one V-belt. Do as follows to
change the V-belt:

1. Remove the cutting unit, see page 30.

2. Undo the bolt on the lift strut and the two screws

on the cover. Lift the cover off the cutting unit.

3. Loosen the spring that tensions the V-belt and

pry off the belt.

Simply reverse the procedure to fit the new belt.

6016-111

6012-079

8009-287

6012-080

Advertising