Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350

2-5. REFRIGERANT
INFORMATION

Design Pressure

Refrigerant Type Amount of Refrig. High Low

BCC-140

R404A

6 lbs. (2.7 kg)

406 psig

102psig

(28 bar)

(7 bar)

BCC-175

R404A

5.5 lbs. (2.4 kg)

406 psig

102 psig

(28 bar)

(7 bar)

2-6. REFRIGERATION

BCC/BCR-140

CAPACITIES

-4

o

F (-20

o

C) at 6,800 BTU/hr (2.0 kw)

32

o

F (0

o

C) at 16,000 BTU/hr (4.7 kw)

BCC/BCR-175

-4

o

F (-20

o

C) at 11,300 BTU/hr (3.3 kw)

32

o

F (0

o

C) at 30,800 BTU/hr (9.0 kw)

BCR-350

-4

o

F (-20

o

C) at 25,000 BTU/hr (7.3 kw)

32

o

F (0

o

C) at 58,000 BTU/hr (17.0 kw)

BFR-350

-4

o

F (-20

o

C) at 81,900 BTU/hr (24.0 kw)

-40

o

F (-40

o

C) at 35,500 BTU/hr (10.4 kw)

2-6

1105

2-7. BCC-175 WATER SUPPLY
AND DRAIN

Water Supply
• Water temperature should be at 50

o

F (10

o

C) + 5

o

)

• 1/2”-14 (15mm/21) diameter water supply
• 29 psi (2 bar) minimum pressure; 73 maxmum (5 bar)
• Supply inlet connector 3/8”-18 (12mm/17)
• 24.7 foot3/hour (0,7 m3/hour) minimum flow rate

Check the operation of the pressure valve. Water should not flow
after the compressor stops. Adjust the valve where necessary,
checking the condensation pressure.

Do not change any supply fittings or lines installed by the manu-
facture, or damage to the unit could result.

Do not use a flexible connection to make a drain trap, or water
overflowing the drain could result.