Henny Penny BFR/BCR-350 User Manual

Page 32

Advertising
background image

Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350

4-2. ALARM MESSAGES

In the event of a system failure, the digital display will show an
alarm message. These messages are coded; “AL-1”, “AL-2”,
“AL-3”, “AL-5”, and “AL-6.” When an alarm occurs, the red
alarm LED will illuminate and a buzzer (optional) will sound. Press
the Alarm button to stop the buzzer.

The unit can operate on auto backup if an alarm sounds for a
faulty probe. Must select the Timer Mode, and enter a time.

Display

Cause

Correction

“AL-1”

Faulty air temperature

Replace the probe; unit can operate on auto

probe

backup until a new probe is installed

“AL-2”

Faulty evaporator probe

Replace the probe; the De-icing Cycle can operate at
50% of the setting in step 7 of the Programming Section

“AL-3”

Faulty Frigiprobe

Replace the probe; the Frigiprobe Mode will not
operate, but the unit will operate in the Timer Mode

“AL-5”

Temperature too low

Faulty control board - replace control board;

in the hold mode

faulty contactor - replace contactor

“AL-6”

Temperature too high in

Faulty control board - replace control board;

the hold mode

door opened too much - make sure door stays
closed as much as possible

4-2