Terminal description, Wiring – Honeywell TRUDRY DR90 User Manual

Page 9

Advertising
background image

Terminal Description

*

nOTE: The outer screws on the terminal block

secure the block to the chassis. They are not
used for wiring.

A wiring terminal block is located on the side
panel of the TrueDRY unit.
The four terminals for the terminal block (reading

from left to right in the photo) are:
DHUM: Compressor and fan operation for

dehumidification

R: DR90 24V output

FAN: Fan activation only for ventilation

C: DR90 24V output

External 24V devices can be powered from R and

C terminals (20VA max.)

Wiring

Wire the TrueDRY DR90 according to the diagram that applies to your desired opera-
tion.

TrueDry DR90 Dehumidification System 69-2407—01

7

TrueDRY

HVAC

THERMOSTAT

G

Y

W

R

C

M29839

DHUM

+

+

R FAN C

C
Rc
R
H
H
DH
DH

W
W2
Y
Y2
G

K

NOTE: THERMOSTAT MUST BE CONFIGURED TO DRIVE FURNACE FAN

DURING DEHUMIDIFICATION CALL.

Follow this diagram if using the

Prestige™ thermostat.

CAuTIOn: low voltage hazard.
Can cause equipment damage.
Disconnect hVAC equipment before beginning installation
.