WARNING

Always protect the valve body by using a damp cloth to prevent the valve
from overheating. Do not braze with the valve body exceeding 275°F (135°
C).

8) Install the new drier (see “4. DRIER”).

9) Check for leaks using nitrogen gas (10 bar) and soap bubbles.

10) Evacuate the system and charge it with refrigerant (see “1. [c] EVACUATION AND

RECHARGE”).

11) Attach the solenoid coil to the valve body, and secure it with the screw.

12) Connect the lead wires.

13) Refi t the panels in their correct positions.

14) Plug in the icemaker or connect the power source.