Hoshizaki KM-260BAH User Manual

Page 77

Advertising
background image

72

VI. CLEANING AND MAINTENANCE INSTRUCTIONS

IMPORTANT

Ensure all components, fasteners and screws are securely in place after
any maintenance or cleaning is done to the equipment.

1. CLEANING

WARNING

1. Hoshizaki recommends cleaning this unit at least once a year. More

frequent cleaning, however, may be required in some existing water
conditions.

2. To prevent injury to individuals and damage to the icemaker, do not use

ammonia type cleaners.

3. Always wear liquid-proof gloves to prevent the cleaning and sanitizing

solutions from coming into contact with skin.

4. For safety and maximum effectiveness, use cleaning and sanitizing

solutions immediately after dilution.

[a] CLEANING PROCEDURE

1) Dilute 5 fl . oz. (148 ml) of recommended cleaner Hoshizaki “Scale Away” or “LIME-

A-WAY” (Economics Laboratory, Inc.) with 1 gal. (3.8 lit.) of water.

2) Remove the louver. Open the door and remove all ice from the evaporator and the

storage bin.

Note: To remove cubes on the evaporator, move the control switch on the control

box to the “OFF” position and move it back to the “ICE” position after 3
minutes. The defrost cycle starts and the cubes will be removed from the
evaporator.

3) Move the control switch to the “OFF” position.

4) Move the control switch to the “SERVICE” position and the service switch to the

“DRAIN” position.

5) After 2 minutes, move the control switch to the “OFF” position.