14. DRAIN VALVE, CLEANING VALVE

1) Unplug the icemaker or disconnect the power source.

2) Close the water supply tap.

3) Remove the top panel, rear panel and side panel (R).

4) Disconnect the tab terminals.

5) Remove the hose clamps at the inlet and outlet sides.

6) Remove the rubber hoses at the inlet and outlet sides.

7) Remove the two mounting screws.

8) Install the new valve in the reverse order of the removal procedure.

9) Open the water supply tap.

10) Plug in the icemaker or connect the power source.

11) Check for leaks.

12) Refi t the panels in their correct positions.