10. remote amperage control receptacle, 11. electrical service guide – Hobart Welding Products BETASTICK 500 User Manual

Page 21

Advertising
background image

OM-201 444 Page 17

3-10. Remote Amperage Control Receptacle

1

2

1

Remote Amperage Control
Receptacle RC1

2

Keyway

To connect remote amperage con-
trol to receptacle, insert plug and
turn clockwise until tight.

Ref. ST-800 040

3-11. Electrical Service Guide

50 Hertz Models

500 Amp Model

Input Voltage

220

380

440

Input Amperes At Rated Output

103

60

51

Max Recommended Standard Fuse Rating In Amperes

1

Time-Delay

2

100

60

50

Normal Operating 3

125

70

60

Min Input Conductor Size In AWG/Kcmil

4

8

8

Max Recommended Input Conductor Length In Feet (Meters)

193

(59)

258

(79)

346

(105)

Min Grounding Conductor Size In AWG/Kcmil

6

8

10

Reference: 1999 National Electrical Code (NEC)

1 Consult factory for circuit breaker applications.

2 “Time-Delay” fuses are UL class “RK5” .
3 “Normal Operating” (general purpose – no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and

above).

Advertising