B. Connecting Input Power

Have only qualified persons make
this installation.

Open rear panel access door.

1

Line Disconnect Device Of
Proper Rating

2

Input Conductors

3

Grounding Conductor

Select size and length using 3-11.
Conductor rating must comply with
national, state, and local electrical
codes. Use lugs of proper amper-
age capacity and correct hole size.

4

Strain Relief Connector

Insert conductors through strain
relief.

5

Input Terminal Board

6

Line Terminals

7

Welding Power Source
Ground Terminal

Connect grounding conductor to
ground terminal first. Then connect
input conductors to line terminals.

8

Disconnect Device Ground
Terminal

Install and connect grounding
conductor and input conductors in
conduit or equivalent to deener-
gized line disconnect device.

Connect grounding conductor first,
then line input conductors.

Be sure grounding conductor goes
to an earth ground.

Close rear panel door.

9

Overcurrent Protection

Select type and size using 3-11.
Install into deenergized line discon-
nect device (fused disconnect
switch shown).

1

9

3

4

8

5

3

2

7

6

Tools Needed:

3/8, 7/16, 1/2 in

ssb2.4 1/94 – ST-800 042-A

Connect GND/PE
Conductor First.