About your new thermostat, Wiring—heat pump – Honeywell RTH7600 User Manual
Page 24
                                    Advertising
                                    
                                        
                                    
                                
                                 
Advanced Installation Guide
69-2206ES—01
22
About your new thermostat
SETUP
WIRING
ASSIST
ANCE
TROUBLESHOOTING
Connect wires: Heat Pump
1. Match each labeled wire with same letter on new 
thermostat.
2. Use a screwdriver to loosen screws, insert wires into
hole, then tighten screws.
3. If E and Aux do not each have a wire connected,
use a small piece of wire to connect them to each
other.
4. Push any excess wire back into the wall opening.
Labels don’t match?
If labels do not match letters on thermostat, see page
23.
M28104
Aux
E
L
C
G
Y
O/B
RC
R
LABELED WIRES
SCREW
HEAT PUMP
INSERT WIRES
THEN TIGHTEN SCREWS
WIRE HOLE
Y
G
R
Au
x
O
HEAT PUMP
Wiring—heat pump