background image

UNIX nodes: OB_CheckFile_UX starts ob_spi_file.sh

Windows systems

Checks if the following files exist in subdirectories of the Data Protector configuration
directory (default: system_drive\Program Files\OmniBack\Config\):

For Data Protector 5.1 and earlier:

cell\cell_info

cell\cell_server

cell\installation_servers

users\userlist

users\classspec

users\webaccess

snmp\OVdests

snmp\OVfilter

options\global

options\trace

For Data Protector 5.5 and later:

Server\cell\cell_info

Server\cell\cell_server

Server\cell\installation_servers

Server\users\userlist

Server\users\classspec

Server\users\webaccess

Server\snmp\OVdests

Server\snmp\OVfilter

Server\options\global

Server\options\trace

Polling interval: 15 minutes

The value for OBHOME is read by ob_spi_file.exe from the registry key:

HKLM\SOFTWARE\Hewlett-Packard\OpenView\\OmniBackII\ Common

HomeDir REG_SZ: “system_drive\Program Files\OmniBack”

Integration guide for HP Operations Manager for Windows