Gathering data from data protector, Generating reports, Viewing reports – HP A.06.10 User Manual

Page 80: 80 generating reports, 80 viewing reports

Advertising
background image

Ensure the database table DPCELLS is present.

If the tables do not exists, create/recreate them using the
following commands:

newdb

-xml

INSTALL_DIR\newconfig\

Packages\DPCELLS.xml

and

newdb -xml

INSTALL_DIR\newconfig\

Packages\DPTREND.xml

Action

Cell Manager already exists in the Reporter

database!! Error Code: 23000

Error message

A Data Protector Cell Manager is already registered with
ReporterLite, and you cannot use this application to update the
information.

Description

To add the same Data Protector Cell Manager, with different
information, remove the existing information from the database
and then add the new information.

To remove (de-register) a Cell Manager, use the AddCell.exe
application, enter the relevant details and click Remove Cell.

Once the Cell Manager is de-registered, data for reports can no
longer be collected from it.

Action

Gathering data from Data Protector

Once Data Protector Cell Managers are registered to ReporterLite, the utility
DPGather.exe

collects data from them. It is launched automatically when required.

Generating reports

ReporterLite utility Repcrys.exe generates reports. It is launched automatically
when required.

Viewing reports

Use the following link to view generated reports:

ReporterLite integration

80