OM-318 Page 11

2-4.

Selecting A Location

1

Lifting Eye

2

Lifting Forks

Use lifting eye or lifting forks to
move unit.

If using lifting forks, extend forks
beyond opposite side of unit.

OR

1

2

Movement

ST-800 402 / ST-130 172-C

3

Location And Airflow

18 in

4

(460 mm)

18 in

(460 mm)

3

Rating Label (Under Access
Door)

Use rating label to determine input
power needs.

4

Line Disconnect Device

Locate unit near correct input pow-
er supply.

Y

Special installation may be
required where gasoline or
volatile liquids are present –
see NEC Article 511 or CEC
Section 20.

2-5.

Dimensions And Weights

Dimensions

A

Height

30-3/4 in (781 mm)

B

Width

19-3/4 in (502 mm)

E

D

C

Length

27-1/2 in (698 mm)

A

27 in (686 mm)

B

26 in (661 mm)

F

C

25-1/4 in (642 mm)

F

Front

D

1-1/2 in (38 mm)

G

E

1-1/8 (29 mm)

F

17-7/8 (454 mm)

G

19-1/4 (489 mm)

H

1/2 in (13 mm) Dia

Ref. ST-154 792-B

6 Holes

H

Weight

370 lbs (168 kg)