C. Installing Heat Shield and Horizontal Termination Cap

NOTE: Where required, an exterior wall fl ashing is
available.

When penetrating a brick wall, a brick extension kit
is available for framing the brick.

Heat Shield Requirements for Horizontal Termination

For all horizontally vented appliances, a heat shield MUST
be placed one inch above the top of the vent between the
wall shield fi restop and the base of the termination cap.

There are two sections of the heat shield. One section attach-
es to the wall shield fi restop with two screws. The remaining
section is attached to the cap in the same manner.

If the wall thickness does not allow the required 1-1/2
inch heat shield overlap, an extended heat shield must
be used.

The extended heat shield will need to be cut to the thick-
ness of the wall and be attached to the wall shield fi restop.
The small leg on the extended heat shield should rest on
the top of the vent (pipe section) to properly space it from
the pipe section (see Figure 8.12).

Installing the Horizontal Termination Cap

Vent termination must not be recessed in the wall. Siding
may be brought to the edge of the cap base.

Flash and seal as appropriate for siding material at outside
edges of cap.

When installing a horizontal termination cap, follow the cap
location guidelines as prescribed by current ANSI Z223.1
and CAN/CGA-B149 installation codes.

Figure 8.12 Venting through the Wall

WARNING

Burn Risk

• Local codes may require installation of a

cap shield to prevent anything or anyone
from touching the hot cap.

WARNING

WARNING

Fire Hazard

Impaired performance of appliance

• Telescoping

fl ue section of termination

cap MUST be used when connecting pipe
section to termination cap.

• Maintain a 1-1/2 inch minimum overlap on

telescoping fl ue section of termination cap.

Fire Risk
Exhaust Fumes Risk
Impaired Performance of Appliance

• Overlap pipe slip sections at least 1-1/2 inches.

• Use pilot holes for screws.

• Screws must not exceed 1 inch long.

• Pipe may separate if not properly joined.