Warning, Gas information – Hearth and Home Technologies Bravo User Manual

Page 26

Advertising
background image

Hearth & Home Technologies • Bravo, Aztec • InD • 703-900 Rev. N • 8/06

26

NOTE: Have the gas supply line installed in accordance
with local building codes, if any. If not, follow ANSI
223.1. Installation should be done by a qualifi ed installer
approved and/or licensed as required by the locality. (In
the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.)

A. Fuel Conversions

WARNING

Fire Risk.
Explosion Hazard.
High pressure will damage valve.
• Disconnect gas supply piping BEFORE

pressure testing gas line at test pressures
above 1/2 psig.

• Close the manual shutoff valve BEFORE

pressure testing gas line at test pressures
equal to or less than 1/2 psig.

B. Gas Pressures

C. Gas Connection

WARNING

Verify inlet pressures.
• High pressure may cause overfi re

condition.

• Low pressure may cause explosion.
• Verify minimum pressures when other

household gas appliances are operating.

Install regulator upstream of valve if line
pressure is greater than 1/2 psig.

Proper input pressures are required for optimum appliance
performance. Gas line sizing requirements need to be
made following NFPA51.

Gas Information

9

NOTE: Gas line may be run from either side of the appliance
provided the hole in the outer wrap does NOT exceed 2-1/2
inches in diameter and does not penetrate the fi rebox.

NOTE: A listed (and Commonwealth of Massachusetts ap-
proved) 1/2 inch (13mm) T-handle manual shut-off valve and
fl exible gas connector are connected to the 1/2 inch (13mm)
control valve inlet.
• If substituting for these components, please consult

local codes for compliance.

Pressure requirements for appliance are shown in the
table below. Minimum pressures must be met when other
household gas appliances are operating.

Pressure Natural

Gas

Propane

Minimum

5.0 inches

11.0 inches

Inlet Pressure

w.c.

w.c.

Maximum Inlet

14.0 inches

14.0 inches

Gas Pressure

w.c.

w.c.

Manifold

3.5 inches

10.0 inches

Pressure w.c. w.c.

Before making gas connections ensure that appliance be-
ing installed is compatible with the available gas type.

Any natural or propane gas conversions necessary to
meet the appliance and locality needs must be made by
a qualifi ed technician using Hearth & Home Technologies
specifi ed and approved parts.

Refer to Reference Section 16 for location of gas line
access in appliance.

WARNING

Gas Leak Risk
• Support control when attaching pipe to

prevent bending gas line.

NOTE: The gap between supply piping and gas ac-
cess hole may be caulked with high temperature caulk
or stuffed with non-combustible, unfaced insulation to
prevent cold air infi ltration.

Advertising