DECATHLON SERIES GAS FRYERS (CE)

CHAPTER 3: INSTALLATION

3-7

3.5 Gas Connections (cont.)

4. To limit movement of the fryer, restraints independent of the flexible coupling or connector

must be used. Clips are located on the back panel of the fryer for the attachment of
restraints.

5. If disconnection of the restraint is necessary, the restraint must be reconnected after the fryer

has been returned to its originally installed position.


J. After hook up, bleed the gas line of air to ensure that the pilot light will ignite quickly and

evenly.

K. CE Standards: If the unit is to be installed with flexible coupling, use a commercial flexible

coupling certified as NF D 36123 (or other national standard) or a quick disconnect device
certified NF D 36124 (or other national standard).



3.6 Adjustments/Adaptation To Different Gases

WARNING

Qualified personnel

MUST perform any adaptation, modification, or gas conversion,

if required. Failure to use qualified personnel will void the Dean warranty.



A. Proper operation of appliances requires operator to inspect the following adjustments in terms of:

1. Gas inputs and pressures.

2. Voltage and polarities of electrical power supplies.


B. Dean gas fryers are manufactured to use the type of gas and pressure specified on the rating

plate. When changing to a different gas, adaptation must be performed by qualified
personnel.
Failure to use qualified personnel will void the Dean warranty.

WARNING

If gas odors are detected, the gas supply

MUST be shut off at the main shut-off

valve, and the local gas company or authorized service agency contacted for

immediate service.