DECATHLON SERIES GAS FRYERS (CE)

CHAPTER 3: INSTALLATION

3-10

3.6.2 Gas Conversion Procedures (cont.)


When converting from G20 (20 mbar) to G25 (25 mbar), or vice-versa, or G31 (37 mbar) to G31 (50
mbar), the following procedures apply:

? ?

Check pilot-adjustment and adjust as necessary.

? ?

Other adjustments are not necessary.


Conversion from one gas family to another (i.e. changing from natural gas to propane) requires
special components. Obtain the necessary components using the cross-reference in Section 3.8, Gas
Conversion Components.

Conversions can only be executed by qualified, factory-authorized personnel
.

ON Button- Pilot Gas-flow

OFF Button

Pressure flow adjustment

Thermocouple connection

Pilot flow adjustment

Vent tube connection

Use the following component information to convert from natural gas to propane and vice-versa.

Natural Gas to Propane Components

Propane To Natural Gas Components

REF

DESCRIPTION

REF

DESCRIPTION

810-2400

Pilot orifice (16LP)

810-0811

Pilot orifice (26N)

810-2059

Burner orifice

(diameter: 1.51 mm)

810-2060

Burner orifice

(diameter: 2.40 mm)

New Rating

Plate

Contact factory at time of

conversion.

New Rating

Plate

Contact factory at time of

conversion.

Burner orifices listed are for fryers operating at altitudes of 610 meters or less. For

altitudes greater than 610 meters, contact the factory for the correct orifice size.