Maintenance, troubleshooting, 1 maintenance, Warning – Furuno FCV-1100L User Manual

Page 65

Advertising
background image

5-1

5. MAINTENANCE,

TROUBLESHOOTING

ELECTRICAL SHOCK HAZARD
Do not open the equipment.

Only qualified personnel
should work inside the
equipment.

WARNING

5.1 Maintenance

Regular maintenance is important for continued performance. Important points to
be checked from time to time are shown below.

Maintenance program

Check point

Action

Interval

Transducer cable

If conductors are exposed, replace cable.

Monthly

Power cable plug,
transducer cable
plug

If loosened, secure tightly.

Monthly

Grounding If

corroded,

clean.

Monthly

Ship’s mains
voltage

If out of ratings, correct problem.

Monthly

Display unit
cleanliness

Dust or dirt may be removed with a soft
cloth. Water-diluted mild detergent may be
used if desired. DO NOT use chemical
cleaners to clean the display unit; they may
remove paint and markings. Use special care
when cleaning the LCD, since it scratches
easily.

Monthly

Transducer
cleanliness

Marine life on the transducer will result in a
gradual decrease in sensitivity. Check the
transducer face each time the boat is
dry-docked. Carefully remove any marine life
with piece of wood or fine sandpaper.

At dry-dock

Advertising