4 diagnostic test – Furuno FCV-1100L User Manual

Page 67

Advertising
background image

5. MAINTENANCE, TROUBLESHOOTING


5-3

5.4 Diagnostic

Test

The diagnostic test checks the equipment for proper operation.

1. Rotate the [FUNCTION] switch fully clockwise to select MENU.
2. Press the [▲] key to select the menu title area at the top of screen.
3. Press the [+] key to select SYSTEM.
4. Press the [▲] or [▼] key to select TEST MODE.
5. Press the [+] key to open the TEST menu.

DISP ALM TX/RX E/S

SYSTEM

Menu for diagnostics.

[-/+]: Change set, [EXIT]: Exit

TEST MODE

DIAGNOSTICS

:

NO

TEST PATTERN : NO

HI FREQ

HI FREQ

: 200 kHz

: 200 kHz

LOW FREQ

LOW FREQ

: 50 kHz

: 50 kHz

Press and hold [MARKER] key more than
3 sec to exit from TEST MODE.

Test menu

6. Press the [+] key twice to select YES in the setting window.

[ ] : YES

[ ] : NO

Test setting window

7. The ROM, SRAM, DRAM and NMEA check results appear. Water

temperature and speed also appear if appropriate sensor is connected.

Program No.

0252307-03.XX

R O M

OK

S R A M

OK

D R A M

OK

N M E A

OK*

Temp. SENSOR

+85.5˚F

Speed SENSOR 8.0 kt

Press and hold [MARKER] key more than 3 sec to exit.

XX: Version No.
*: Requires special cable to check.

O O O 238
O 8 O 6
* O O O 255

ROM, SRAM, DRAM and NMEA test
results are shown as OK or NG (No Good).

Panel window
For testing controls.
See next page.

Diagnostic test results