2 fuse replacement, 3 troubleshooting, Caution – Furuno FCV-1100L User Manual

Page 66

Advertising
background image

5. MAINTENANCE, TROUBLESHOOTING

5-2

5.2 Fuse

Replacement

A 5A fuse (type: FGBO-A 5A AC125V) in the power cable protects the equipment
against overcurrent, reverse polarity of the ship’s mains and internal fault. If the fuse
blows find the cause before replacing it. Contact your dealer about replacement. (A
7A fuse (type: FGMB 7A 125V) also is contained inside the display unit. Contact
your dealer about its replacement.)

CAUTION

Use the proper fuse.

Use of a wrong fuse can cause fire or
damage the equipment.


5.3 Troubleshooting

This section provides simple troubleshooting procedures which the user may
follow to restore normal operation.

Troubleshooting

If… Then…

there are no echoes but
the depth scale appears

check if the transducer is properly connected.

there is no zero line or
zero line is not in correct
position

check if the range shifted. (Zero line does not appear when

the range is shifted.)

press the [-] key so as the scale starts from 0.

you suspect poor or low
sensitivity

check that the [GAIN] control is properly set.

the bottom is traced in
zigzag pattern or you
experience occasional
loss of echo

the sea may be rough. Bottom is traced zigzag when the sea

is rough.

own boat may have passed over other boat’s wake, which

blocks propagation of sound wave.

there is no depth readout

check to see if bottom is present on the normal picture range.

check if bottom echo is painted in red, reddish-brown.

automatic shift is
inoperative

check if bottom echo is painted in red, reddish-brown.

noise appear
intermittently

check if the cables of pulse generating equipment are near

the equipment.

there is noise and
interference

check that GAIN and CLUTTER are properly adjusted.

check the setting of the noise limiter.

check the equipment’s ground.

Advertising