125

CHAPTER2 Dependence Functions

The sequencer operates as shown below when it uses the real-time monitoring bus interface:

[Setup Example]

>SET SEQUENCE 1.3.2, r=4

Events 1, 3, and 2 are specified respectively for Levels 1, 2, and 3. Event 4 is specified as a restart
condition.

Setting Sequencer

The sequencer can be set by the dialog or the command.

Setting by dialog

Select [Debug] - [Sequence] menu.

For details, refer to "4.6.6 Sequence" in "SOFTUNE Workbench Operation Manual".

Setting by Command

1. The event is set according to the SET EVENT command.

2. The event set by the SET SEQUENCE command is set as a sequence.

For details, refer to "3.15 SET EVENT" or "3.31 SET SEQUENCE (type2)" in "SOFTUNE Workbench
Command Reference Manual".

Start

Event 1

NO

Level 1

YES

Event 3

NO

Level 2

YES

Event 2

NO

Level 3

YES

Event 4

YES

Event 4

YES

Break

NO

NO