CHAPTER2 Dependence Functions

Specifications of Sequencer

Table 2.4-2 shows the specifications of the sequencer for the emulator debugger (MB2100-01).

Setting

Sequencer control can be set as follows.

Dialog

- Sequence Setup Dialog

For details, refer to "4.6.6 Sequence" in "SOFTUNE Workbench Operation Manual".

Command

1. SET EVENT

2. SET SEQUENCE

For details, refer to "3.15 SET EVENT" or "3.31 SET SEQUENCE (type2)" in "SOFTUNE Workbench

Command Reference Manual".

Notes:

When the pass count mode is a passing count break mode, this function cannot be used.

For details, refer to "2.4.3.2 Switching Debug Function".

Depending on the output timing of external trace data, the actual order of code execution may
change places with the order of data hit information. For this reason, if a code event and a data
event occur close to each other, normal transition may not occur.

A sequencer shares points with the following functions. The maximum number of sequencer
varies depending on how those functions are used.

- Code break

- Data break

- Data watch break

- Trace trigger

If a data event is set to the sequencer, the data event may stop after a few steps of instructions
following the instruction with detection access are executed.

Table 2.4-2 Specifications of Sequencer

Function

Specification

No. of levels

2 levels

Restart function

Available (one)

Conditions of each
event
(Code/data)

Address
Pass count : 1 to 1048575
Attribute

: Read/write

Data size

: Byte, half-word, word

(Attribute and data size can be specified only for data events.)

Operation when
conditions are met

Level 1 : Moves to level 2
Level 2 : Terminates the sequencer
Restart : Starts the sequencer