3–12

6. To EXIT and SAVE the product name entry, press the

switch.

SAVE will flash in the right

display, followed by

YES or NO, indicating whether the menu item is active or not. Press the

right

1

or

2

switch to toggle between yes and no.


7. Press the

switch to cycle through the Duty Times, Pull Time, QA (hold) Time, and Cooking

Temperature Setpoint settings. Program the times and the set point in accordance with the section
that follows.

How to Program Duty Times, Pull Time, QA Time, and Setpoint for a Test Menu Item

NOTE: Duty Time refers to an operator-specified time within a cooking cycle when the computer
will sound an alarm to prompt a particular duty such as shaking the basket.

1. Enter the program mode. See How to Enter the Program Mode on page 3-10.

2. Press the

switch to select the desired test menu.

3. Press the

switch.

DUTY1 will appear in the left display. The currently programmed time

appears in the right display. To program the time, use the following switches:

Left

Minutes (in increments of ten)

Left

1

Minutes (in increments of one)

Left

2

Seconds (in increments of ten)

Right

1

Seconds (in increments of one)


Press

the

right

2

switch to toggle between the manual alarm cancel mode (

MAN) and the

automatic alarm cancel mode (

AUTO).


NOTE:
In the automatic alarm cancel mode (

AUTO), when the programmed time has elapsed,

an audible alarm will sound three times and then stop. In the manual alarm cancel mode (

MAN),

when the programmed time has elapsed, an audible alarm will sound until the operator presses the
cook switch (

1

or

2

) that was pressed to start the cooking cycle.


4. Press the

switch,

DUTY2 appears in the left display. The currently programmed time appears

in the right display. Program the time in the same manner as Duty1 time.


NOTE: Enter a time of

00:00 to bypass this option.


NOTE:

In the steps that follow, Pull Time refers to the programmed time at which the product is

fully cooked and an audible alarm will prompt removal of the basket from the cooking oil. QA
Time
refers to the maximum time that a product may be held after the cooking cycle has
completed.


5. Press the

switch to display

PULL in the left window. Program the pull time in the same

manner as the duty times.


6. Press the

switch to display

QA in the left window. Program the QA time in the same manner

as the duty times.