Fryer Heating Oil

COMPUTER

PANEL OPEN

INTERFACE

BOARD VISIBLE

Initiate HEAT MODE by

turning the fyrer on and setting

the temperature at least 45° F

(24° C) above the temperature

of the cooking oil.

Is the HEATING MODE indicator lit with LOW TEMP

displayed in computer window?

NOTE: Indicator may cycle on and off and LOW TEMP

may alternate with the product name.

1. Product name displayed constantly indicates

oil temperature is within 45° F (24° C) of set-
point.

2. HOT HI 1 indicates the oil temperature is

higher than 410° F/210° C (395° F/202° C for
European Community).

3. 3. PROBE FAILURE indicates a problem in

the temperature-measuing circuitry, including
the probe.

4. IGNITION FAILURE indicates a problem with

the latching relay on the interface board or
the latching contactor.

Probable causes are:

1. Defective computer
2. Broken or improper wire connection

NO

YES

Is the 3-phase power cord plugged in properly?

Is the circuit breaker in the 3-phase circuit closed?

Probable causes are:

1. Unplugged 3-phase power cord
2. Defective or shorted circuit

NO

Continued on

next page

YES

Advertising