Fryer heating oil – Frymaster H14 Series User Manual

Page 47

Advertising
background image

6-7

Fryer Heating Oil

CONTROLLER

PANEL OPEN

INTERFACE

BOARD VISIBLE

Initiate HEAT MODE by

turning the fyrer on and setting

the temperature at least 45° F

(24° C) above the temperature

of the cooking oil.

Is the HEATING MODE indicator lit with the POWER

indicator on?

NOTE: Indicator may cycle on and off.

1. TROUBLE LIGHT indicates:

a.

Oil temperature is higher than 410° F/
210° C

b.

There is a problem in the temperature
measuring circuitry, including the probe.

2. HEATING MODE indicator and TROUBLE

LIGHT on at the same time indicates a
problem with the latching relay on the
interface board or the latching contactor.

Probable causes are:

1. Defective controller
2. Broken or improper wire connection

NO

YES

Is the 3-phase power cord plugged in properly?

Is the circuit breaker in the 3-phase circuit closed?

Probable causes are:

1. Unplugged 3-phase power cord
2. Defective or shorted circuit