5-6

Return handle and drain-valve handle
location.

With fryer off, open drain valve.

When frypot empties into filter pan, turn
return handle to ON. Filter pump will
activate.

Turn the computer back ON and use right
arrow key

to step through selection,

stopping on FILTER. Press right

1

button to

initiate five-minute timer for filtering.