Pump motor actuation, Filter system operation – Frymaster H14 Series User Manual

Page 50

Advertising
background image

6-10

6.2.3

Troubleshooting the Built-in Filtration System (BIH14 units only)

MOMENTARILY

TURN THE FILTER

HANDLE TO THE

ON POSITION

Does the pump

start?

Probable causes are:

1. No Line Voltage to motor:

a. Broken or improper wire connection
b. Relay not closing due to:

(1) Missing 24V
(2) Broken or improper wire connection
(3) Pump microswitch open or defective
(4) Defective 24V transformer

c. Defective relay

2. Thermal overload tripped
3. Clogged pump
4. Defective motor

Condition normal.

Pump Motor Actuation

ASSEMBLE PAN AND
DRAIN COOKING OIL

FROM ONE FRYPOT

INTO FILTER PAN. TURN

THE PUMP HANDLE ON

THE SELECTED FRYPOT

TO THE "ON" POSITION.

Does oil return to the

selected frypot

satisfactorily?

Condition normal.

What

happens?

Oil returns slowly.

No oil is returned.

Oil returns to

wrong frypot or to

more than one

frypot.

Probable causes are:
1. Oil return lines blocked or kinked
2. Misadjusted oil return valve linkage
3. Blocked drain-pan check-valve

Probable causes are:
1. Oil return lines partially blocked or

kinked

2. Misadjusted oil return valve linkage
3. Blocked drain-pan check-valve
4. Missing or defective O-ring
5. Incorrect paper/pad
6. Clogged filter screen
7. Filter pan improperly assembled

Probable causes are:
1. Wrong filter handle turned
2. Misadjusted oil return valve linkage

on unintended frypot (valve does not
close fully).

3. Defective oil return valve on

unintended frypot (valve does not
close fully).

Filter System Operation

NO

YES

NO

YES

Advertising