Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS

CHAPTER 4: DAILY OPERATION

4-2

4.2 Start-Up Procedures (cont.)

B. Pilot lighting procedure – Electronic Ignition

a. Turn gas "ON."

b. Turn electric power "ON" with the appropriate rocker switch or

controller/controller.

c. The ignition module will energize the pilot gas supply and the ignitor. The ignitor

spark will ignite the pilot gas. The presence of the pilot flame is then proven by a
flame sensor, which sends a signal to the main gas supply, opening the valve. The
operating thermostat or controller/controller controls the fryer after ignition.


WARNING

In the event of prolonged power failure, the ignition module will shut down and lock

out the system. Turn the unit power "OFF" and then back "ON" after power has

been re-established.


d. If the pilot flame fails, the ignition module will shut down and lock out the system.

To restart, turn the electric power "OFF,” wait approximately 5 minutes for the
system to recycle itself, and then turn the power "ON" again. Repeat Steps a-c.


3. KFC-1 Cooking Controller: Turn the controller ON and select cooking program as

described in the KFC-1 SMS Cooking Controller User Guide.



NOTE: For FAST-equipped fryers, see the Fast manual for operation instructions.