2 fryer troubleshooting (cont.), Burner tube – Frymaster Y/KSCF/C/HC18G User Manual

Page 45

Advertising
background image

Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS

CHAPTER 7: TROUBLESHOOTING

7-4

7.2 Fryer Troubleshooting (cont.)

Fr
ypot Fr

ont

High-Limit

Probe

Temperature

Probe



No: Ensure the probe tip is ⅛" from the
top of the burner tubes (see illustration).
If the probe adjustment is correct, the
controller probe circuit may be faulty.
If probe adjustment is incorrect, it will
require adjustment.


6. Contact your authorized service agent if

any of the following occurs during this test:

a. Controller probe circuit is suspected

as faulty.


b. Temperature probe needs adjustment.

c. KFC-1 SMS controller fails to call

for heat during the calibration test.