Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS

CHAPTER 7: TROUBLESHOOTING

7-6

Fryer Troubleshooting (cont.)

7.2.6

Main burner malfunctions.

A. Main burner will not ignite; no gas is

present at main burner.

1. Check that float switch is not stuck

in the "down" position.

2. Check and reset the high-limit

switch.

3. The combination gas valve and/or

electronic ignition system may be
defective; Contact a FAS for
service.


B. Main burner flames are small and

appear lazy; shortening does not come
up to temperature quickly. Contact a
FAS for service.


C. Fryer will not reach setpoint

temperature and/or runs erratically.

1. Incorrect location or adjustment of

sensor probe. Contact a FAS for
service.

2. Defective temperature sensor. Contact

a FAS for service.


D. Fryer shortening temperature cannot be

controlled; fryer runs at high-limit
temperature. Possible causes are:

1. Defective operating thermostat.

Contact a FAS for service.


2. Defective temperature probe.

Contact a FAS for service.