Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS

CHAPTER 7: TROUBLESHOOTING

7-5

7.2 Fryer Troubleshooting (cont.)


7.2.4

DRAIN OPEN message
remains after closing drain
valve.

1. KFC-1 SMS controller was turned OFF

while draining frypot.

2. Close drain valve. Turn KFC-1 SMS

controller OFF and ON again.
Controller display will read ON.

3. Open drain valve. The KFC-1 SMS

controller display will read DRAIN
OPEN. After 30 seconds the controller
display will read FILL.

4. Close drain valve.

5. Fill frypot with shortening. Press

EXIT/COOL FILTER when ready to
cook.

6. If the KFC-1 SMS controller message

DRAIN OPEN remains after Steps 1-
4, contact an authorized service agent.
Possible malfunctions are:

a. Drain microswitch may be faulty.

b. Drain circuit is suspect.

c. KFC-1 SMS controller is suspect.

7.2.5

Pump motor won’t start or
stops during filtering.

1.

The motor thermal overload has tripped. If
the thermal overload trips, wait
approximately 45 minutes. Press the
button on the end of the filter motor.

2. If you have to do this repeatedly, stop

resetting the overload and contact an
authorized service agent.

NOTE:

This is usually caused by allowing

large particles of food to enter the pump
during filtering. Ensure that the filter paper
and crumb screen are properly in place.