Alarms, 1 arrival alarm, anchor watch alarm – Furuno GPS NAVIGATOR GP-150 User Manual

Page 45

Advertising
background image



7-1

7. ALARMS

There are seven alarm conditions which
generate both audible and visual alarms.
When an alarm setting is violated, the buzzer
sounds and the name of the offending alarm
appears on the display. The alarm icon also
appears on the Plotter 1, Plotter 2 and
Highway displays.

234.0

°

BRG

345.0

°

123

12.3

SOG

NM

COG

Arrival Alarm

Speed Alarm

Press CLEAR to silence beep

Press CLEAR

Alarm message

Alarm
icon

34

° 23.456´ N 135° 45.678´ E

RNG

D3D 100m

* SAFE

kn

Press CLEAR to close window

Figure 7-1 Location of alarm messages and

alarm icon

7.1 Arrival

Alarm,

Anchor

Watch Alarm

Arrival alarm

The arrival alarm informs you that own ship
is approaching a destination waypoint. The
area that defines an arrival zone is that of a
circle which you approach from the outside
of the circle. The alarm will be released if
own ship enters the circle.

Own ship’s
position

Destination

waypoint

: Alarm range

Alarm
setting

Figure 7-2 How the arrival alarm works

1) Press the MENU ESC key.
2) Press 4 to display the ALARM

SETTINGS menu.

Arrival/Anchor ARRV ANCH Off
Alarm Range 0.100NM
XTE On Off
Alarm Range 0.050NM
Ship Speed In Over Off
Speed Rage 000.0 ~ 025.0kn
To Next Page

ALARM SETTINGS 1/2

Over

Ship Speed

MENU : Escape

: Select

ENT : Enter

Figure 7-3 ALARM SETTINGS

menu, page 1/2


3) Press or

to select Arrival/Anchor.

4) Press or to select ARRV.
5) Press to select Alarm Range.
6) Key in alarm range (0.001-9.999 NM).
7) Press the NU/CU ENT key.
8) Press the MENU ESC key.
When own ship nears a waypoint by the
range set here, the buzzer sounds and the
message "Arrival Alarm" appears. You can
silence the audible alarm by pressing the
CLEAR key. To erase the visual alarm, press
the CLEAR key again.
To disable the alarm, select Off at step 5.

Advertising