General operating problems, Communications, troubleshooting – Meridian Audio 565 User Manual

Page 58

Advertising
background image

54

Troubleshooting

Standby point not lit

Check the following:

❍ There is AC power connected to the socket on the rear of the

565.

❍ The power switch on the rear panel of the 565 is turned on.

If the 565 will still not illuminate, check any fuses in your power

supply and the fuse in the inlet of the 565. If these are all intact,

contact your dealer.

Remote not working

Check the following:

❍ The battery in the Meridian System Remote.
❍ Remove the 500 comms connections from the 565, does it

respond now? If so, replace the connections and perform an

Auto Configure procedure; see Connecting to other Meridian

equipment, page 18.

See if the 565 is set to Not Controller in Config; see To set

other configuration options, page 27. Note that this may be

deliberate by your dealer.

Communications not working with
other Meridian products

❍ Check the connections carefully.
❍ Are you using a mix of 200 and 500 Series units?

Erratic or unexpected system
behaviour

Redo the Auto Configure process; see Connecting to other

Meridian equipment, page 18.

If this fails, the memory of the 565 may have been corrupted. If

this is suspected perform a full reset.

I am playing a Dolby Digital DVD, but
the 565 selects the Pro Logic preset

DVDs include a 2-channel Dolby Digital soundtrack, which will

use the default 2-channel preset.

❍ Select a 6-channel soundtrack, if it is available.

General operating problems