Frymaster D User Manual

Page 10

Advertising
background image

DECATHLON SERIES GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1-5

Interface Boards

(cont.)


IFB 106-6669 & 106-6710:
These interface boards are used in Decathlon fryers with Frymaster
computer control systems.

INTERFACE BOARD P/N 106-6669

INTERFACE BOARD P/N 106-6710

FREQUENTLY USED TEST POINTS FOR INTERFACE BOARD P/N 806-4549 (previous style)

Test Meter

Setting

Pins

Test

Results

12VAC Power to Controller

50VAC Scale

1 and 3 on J3

12-18

24VAC Power to Right Module

50VAC Scale

8 on J3 and GROUND

22-28

24VAC Power to Left Module

50VAC Scale

8 on J1 and GROUND

22-28

12VDC Power to Right BL Relay

50VDC Scale

7 on J2 and 9 or 12 on J3

12-18

12VDC Power to Left BL Relay

50VDC Scale

9 on J2 and 9 or 12 on J1

12-18

24VAC Power to Right High-Limit

50VAC Scale

7 on J3 and GROUND

22-28

24VAC Power to Left High-Limit

50VAC Scale

7 on J1 and GROUND

22-28

120VAC Power*

250VAC Scale

11 on J3 and GROUND

110-125

120VAC Power To 120VAC Gas Valve* 250VAC Scale

10 on J3 and GROUND

110-125

Probe Resistance (Right)**

R x 1000 Ohms

2 on J3 and 4 on J3

***

Probe Resistance (Left)**

R x 1000 Ohms

2 on J1 and 4 on J1

***

* Where Applicable

** Disconnect 15-pin harness from controller before testing probe circuit.

*** See Probe Resistance Charts in this chapter.

Advertising
This manual is related to the following products:

FPD