1.7.3 Replacing the Temperature Probe; Computer-equipped Fryers

(cont.)

6. Remove the appropriate burners to gain

access to the temperature probe. (See Steps
20-22 on page 1-27 for more details.)

NOTE: Ensure that the burners are placed in their
original spots when putting them back into the
fryer. (See page 1-28.)








7. Loosen and unscrew the compression nut

and the pass-through nut completely from
the frypot. Proceed to the next step before
removing the probe from the frypot.








8. Remove temperature probe mounting

hardware. Some older pots may use a
spring-bracket combination. Newer pots use
mounting clips. Retain mounting hardware
for installation of new temperature probe.








Older pots have spring-bracket combinations.

Loosen and unscrew completely the compression
nut (bottom arrow), then the pass-through nut (top
arrow).

Newer pots have mounting clips.

Remove burners to gain access to temperature
probe.