CHAPTER 1: SERVICE PROCEDURES

1-19

1.7.4 Replacing the High-limit Thermostat

(cont.)

9. Remove high-limit from fryer by pulling the

capillary tube and bulb through the component box
opening (arrow). This may require removal of the
control panel frame.






10. Reverse the above steps for high-limit installation.

IMPORTANT: When installing new high-limit or
backup thermostat, ensure the capillary tube and bulb
are positioned properly with the mounting hardware
installed prior to tightening the compression nut. Once
tightened, the capillary tube cannot be repositioned.


Component box opening (arrow).

1.7.5 Replacing Rocker Switches

1. Disconnect the fryer from the electrical supply.

2. If the switches are located on front panel, remove the screws securing panel to fryer. Do not

allow the panel to hang on the switch wiring harness; use some type of support. (Figure A) If
the switches are located in a control box within the fryer
, remove the screws securing the
switch panel to the control box. Do not allow the switch panel to hang from the switch wiring
harness. (Figure B)

Remove screws.

Remove the screws holding the plate in place, then
depress the clips on each end to remove the switch.

FIGURE B

FIGURE A

Pass the wires through the switch guard
(if applicable) before connecting to switch.

Switch Guard