Megohmmeter test, Bar–to–bar resistance test, Disassembly armature removal from frame – GE VERTICAL DRILLING MOTOR GE752 User Manual

Page 20

Advertising
background image

GEK–91584D, Vertical Drilling Motor, Type GE752

20

TABLE 2. DRAWING REFERENCE

GE752

Model

Inst.

Book

Longi–
tudinal

Puller Tools

Comm. Pinion

End End

Arm.

Shaft

Connection

Diagram

Coiled

Frame As-

sembly

Bearing Grease

Distribution

Drive Comm.

End End

Arm.

Locking

Arrange-

ment

Outline

AUP1

Fig. 15

Fig. 16

Fig. 17

Fig. 20

Fig. 22

Fig. 29

Fig. 34

Fig. 38

Fig. 43

Fig. 48

AUP2

Fig. 15

Fig. 16

Fig. 17

–––

Fig. 22

Fig. 29

Fig. 34

Fig. 38

Fig. 43

Fig. 48

AUP3

Fig. 15

Fig. 16

Fig. 17

–––

Fig. 22

Fig. 29

Fig. 35

Fig. 38

Fig. 43

Fig. 48

AUP4

Fig. 15

Fig. 16

Fig. 17

–––

Fig. 22

Fig. 29

Fig. 35

Fig. 38

Fig. 43

Fig. 48

AUP5

Fig. 15

Fig. 16

Fig. 17

–––

Fig. 22

Fig. 29

Fig. 35

Fig. 39

Fig. 43

Fig. 48

AUT1

Fig. 18

Fig. 16

Fig. 17

–––

Fig. 24

Fig. 32

Fig. 36

Fig. 38

Fig. 43

Fig. 49

AUT2

Fig. 18

Fig. 16

Fig. 17

–––

Fig. 24

Fig. 32

Fig. 36

Fig. 39

Fig. 43

Fig. 49

UP1

Fig. 15

Fig. 16

Fig. 17

Fig. 20

Fig. 21

Fig. 30

Fig. 34

Fig. 38

Fig. 43

Fig. 48

UP2

Fig. 15

Fig. 16

Fig. 17

–––

Fig. 21

Fig. 30

Fig. 34

Fig. 38

Fig. 43

Fig. 48

UP3

Fig. 15

Fig. 16

Fig. 17

–––

Fig. 21

Fig. 30

Fig. 35

Fig. 38

Fig. 43

Fig. 48

UP3A

Fig. 15

Fig. 16

Fig. 17

–––

Fig. 21

Fig. 30

Fig. 35

Fig. 38

Fig. 43

Fig. 48

UP4

Fig. 15

Fig. 16

Fig. 17

–––

Fig. 21

Fig. 30

Fig. 35

Fig. 38

Fig. 43

Fig. 48

UP5

Fig. 15

Fig. 16

Fig. 17

–––

Fig. 21

Fig. 30

Fig. 35

Fig. 38

Fig. 43

Fig. 48

UP6

Fig. 15

Fig. 16

Fig. 17

–––

Fig. 21

Fig. 30

Fig. 35

Fig. 39

Fig. 43

Fig. 48

US1

Fig. 18

Fig. 16

Fig. 17

–––

Fig. 23

Fig. 31

Fig. 36

Fig. 38

Fig. 43

Fig. 49

US2

Fig. 18

Fig. 16

Fig. 17

–––

Fig. 23

Fig. 31

Fig. 36

Fig. 39

Fig. 43

Fig. 49

Megohmmeter Test

Lift the brushes and perform a megohmmeter test on

the armature windings and field coils to determine the
condition of the insulation. A reading of less than 2
megohms indicates poor insulation, dirt accumulation or
excessive moisture.

Bar–To–Bar Resistance Test

Test for open or short–circuited armature coils.

1.

Pass a regulated d–c current through the arma-
ture coils.

2.

Read the voltage drop between the commutator
bars with a millivoltmeter. if the reading varies
more than +/– 5% from the average value, a de-
fective or short–circuited coil is indicated.

DISASSEMBLY

Armature Removal From Frame

Models UP, AUP

Before turning the machine from horizontal to verti-

cal (or vice–versa), attach the armature locking ar-
rangement to prevent the armature from moving axially.
Remove the armature locking arrangement before op-
erating the machine.

See Table 2 to determine the correct armature lock-

ing arrangement drawing.

Refer to the longitudinal drawing, Fig. 15, and puller

tool drawings, Figs. 16 and 17.

1.

Clean the outside of the frame.

2.

Remove the hubs from the shaft if not already re-
moved.

3.

Remove the commutator covers. Disconnect
and remove all brushes and brushholders. Wrap

Advertising