Vertical Drilling Motor, Type GE752, GEK–91584D

75

FIG. 48. OUTLINE, UP AND AUP (41E903631 CHG. H). E–28755B.

58.50

AIR OUT

9.56

13.43

+

– .06

9.24

F

10.50

23.12

1.38

1.74

8.25

6.50

G

3.19

2.38

– .12

1.00 R.

3.62

7.88

1.06

1.06

+

– .06

G

+

+

– .005

11.375
DIA.

C ARMATURE

L

.50 NPT FOR
AIR PRESSURE
MEASUREMENT

A1

F2

F1

ONE .25 PIPE PLUG–REPLACE
WITH GREASE FITTING FOR

1.56 DIA. THRU
(4 HOLES)

E HOLE

.75–10 TAP THRU
(2 HOLES)
FOR JACKING

FOOT
DIMENSIONS

C MOTOR

L

.562 DIA.
2 HOLES

ARMATURE LOCK
ARRANGEMENT
SEE NOTE

E HOLE

G

A2

NOTE FOR ARMATURE LOCKING ARRANGEMENT
LOCATED ON COMMUTATOR END

TO BE IN PLACE DURING MOUNTING OF MOTOR
BUT TO BE REMOVED BEFORE OPERATION OF
MOTOR

GE–752–AUP SHOWN IN MAIN VIEWS
GE–752–UP SHOWN IN FIG. 1

APPROXIMATE WEIGHTS

GE–752–UP 6750 POUNDS
GE–752–AUP 6850 POUNDS

AIR FLOW REQUIREMENTS

2300 CFM OF STANDARD AIR
MINIMUM 900 HP
2800 CFM OF STANDARD AIR
MINIMUM 1000 HP

IMPORTANT
THE ELECTRICAL EQUIPMENT SHOULD BE
LOCATED IN A SPACE WHICH
(1) PROVIDES SUFFICIENT ACCESSIBILTY
FOR BRUSH INSPECTION
(2) ALLOWS REMOVAL OF ALL THE BRUSHES
AND PIGTAIL FASTENERS
(3) ALLOWS MAINTENANCE PERSONNEL TO
COMPLY TO THE GE MAINTENANCE
INSTRUCTION SPECIAL REQUIREMENTS

REGREASING (ALL MODELS EXCEPT
UP1, UP2, AUP1 AND AUP2)

Advertising