Models G0657/G0658 (Mfg. Since 5/13)

-33-

review the troubleshooting and procedures in this section to fix or adjust your machine if a problem devel-
ops. if you need replacement parts or you are unsure of your repair skills, then feel free to call our technical
support at (570) 546-9663.

SECTiON 7: SERviCE

Troubleshooting

Motor & Electrical

symptom

possible Cause

possible solution

Machine does not
start or a breaker
trips.

1. plug/receptacle is at fault or wired

incorrectly.

2. power supply is at fault/switched

OFF.

3. lockout key is at fault.
4. Motor on button or on/oFF switch is at

fault.

5. Wiring is at fault.

6. Motor brushes are worn.
7. Motor is at fault.

1. test for good contacts; correct the wiring.

2. ensure hot lines have correct voltage on all legs

and main power supply is switched

ON.

3. install/replace lockout key; replace switch.
4. replace faulty on button or on/oFF switch.

5. Check for broken wires or disconnected/corroded

connections, and repair/replace as necessary.

6. replace brushes.
7. test/repair/replace.

Machine stalls or is
overloaded.

1. too much tool pressure.
2. plug/receptacle is at fault.
3. Motor bearings are at fault.

4. Motor brushes are worn.
5. Motor has overheated.
6. Motor is at fault.

1. reduce tool pressure.
2. test for good contacts; correct the wiring.
3. test by rotating shaft; rotational grinding/loose shaft

requires bearing replacement.

4. replace brushes.
5. Clean off motor, let cool, and reduce workload.
6. test/repair/replace.

Machine has
vibration or noisy
operation.

1. Motor or component is loose.

2. Motor fan is rubbing on fan cover.

3. Workpiece or center/chuck is at fault.

4. Motor bearings are at fault.

1. inspect/replace stripped or damaged bolts/nuts, and

re-tighten with thread locking fluid.

2. replace dented fan cover; replace loose/damaged

fan.

3. Center workpiece on center/chuck or face plate;

reduce rpM; replace defective center/chuck.

4. test by rotating shaft; rotational grinding/loose shaft

requires bearing replacement.

Advertising